Welcome to the  NHBOA member site

NHBOA February 12th 2025 Educational Training

  • February 13, 2025
  • 8:30 AM - 12:00 PM
  • 25 Triangle Park Drive, Concord, NH

Registration


Registration is closed

In person and Online Training

Intro to Repetitive Light-Frame Wood Roof Framing

James B. Smith, P.E.

Intuitive Codes and Consulting

Course Description

This presentation will introduce basic engineering principles applicable to light-frame wood construction using both solid sawn lumber and Engineered Wood Products commonly used in the Mid-Atlantic and New England regions. We will discuss the critical concept of load path and how the roof framing system safely transfers lateral load from high wind events through the structural framing system. Best framing practices, Wood Structural Panels (WSP’s), the importance of fasteners, and the continuity of connections will be discussed. Design for Code Acceptance 6 (DCA6)-15 Prescriptive Residential Wood Deck Guide, with 2018 IRC Updates Course Description: Hundreds of wood decks get built every year and some without the proper guidance for designing or constructing a safe deck. However, AWC DCA6-15, which is in the process of being updated, includes guidance on provisions for the 2015 & 2018 International Residential Code (IRC) pertaining to single level residential wood deck construction. Provisions contained in this document that are not included in the IRC are considered good practice. When you get the question “why doesn’t the DCA6 document line up with the 2021 IRC?”, there are a number of reasons. One at the forefront is that the IRC only addresses axial loading of the supporting posts. They do not address bending forces that the DCA6 does. There are some other issues such as span length (the I-Codes measure from the center of the framing member-difficult to fi eld verify, and DCA6 measures from face of member to the contact point of the supporting member). In short, DCA6 is a more conservative document than the IRC. Finally, the standard nailed post base connections have no resistance to lateral loads. They essentially function as a pin connection from a structural engineering standpoint. There are some proprietary post base connections that do provide moment resistance for those loads, but they are very expensive, and they require a very robust reinforcing steel package in the footing. Just some food for thought when you get into Decks in the IRC.

About the Instructor

Mr. Smith is a Professional Engineer registered in the State of Wisconsin and is a code consultant working as Intuitive Codes and Consulting. He continues to assist architects, engineers, organizations, and code officials. Most recently he assisted on a historic building in Gresham, WI, a Mass Timber project in Madison, WI, a multifamily dwelling project in Green Bay, WI, a Justice Center expansion for St. Croix County, WI, and an expansion at a resort in Wisconsin Dells, WI. Jim was the Midwest Regional Manager for the American Wood Council (AWC) beginning in 2014 until his retirement in 2021. Jim provided services to code officials in the States of Ohio, Kentucky, Michigan, Indiana, Wisconsin, Illinois, Minnesota, Iowa, North Dakota, South Dakota, and Washington Prior to his employment with AWC Jim was the Chief Building Official and Zoning Administrator for the City of Waukesha, WI from 2011 until 2014. For almost 32 years Jim was an employee of the State of Wisconsin’s Safety and Buildings Division. He started as a plan examiner and by 2011 was the Program Manager responsible for the Commercial Building, Fire Protection Systems, HVAC and Energy Conservation Programs as well as heading up the Building Material Evaluation operation. For the International Code Council Jim served on two of the Code Development Committees [IBC Means of Egress Code Development Committee and IBC Fire Safety Code Development Committee] for the 2003 edition of the International Building Code [IBC]. For the 2006 edition of the IBC he served on the Means of Egress Code Development Committee. He also served on the ICC Building Code Action Committee that developed code changes for the 2015, 2018, 2021 and 2024 editions of the IBC. For the National Fire Protection Association Jim served on Technical Committees on Building Systems, the Building Code, Mercantile and Business Occupancies, and Industrial, Storage, and Miscellaneous Occupancies.

Agenda:

Check-in (in person & on-line) 8:30 am - 9:00 am

Educational Presentation 9:00 am - 12:00 pm

Board of Directors meeting          12:15 pm - 2:00 pm

Meeting Location:

NHMA – 25 Triangle Park Drive, Concord

In-person & on-line meeting (you will be emailed instructions prior to the training)

Price:

Members: $30 remote, $40 in-person 

Non-Members: $50 (payment required prior to the day of training)

NHBOA is an ICC Preferred Provider - #1087 - 3 Contact Hours

(CEU’s for participation are emailed to attendees upon completion and full payment of registration fee)


The New Hampshire Building Officials Association is a 501(c)6 non-profit organization. 25 Triangle Park Drive, Concord, NH 03301

Privacy Policy | Terms of Use

  • Home
  • NHBOA February 12th 2025 Educational Training
Powered by Wild Apricot Membership Software